Sizes: According to Customer specification.
Ratings: ASME Class: 150 to 2500, DIN: PN 16 to 420
Visible length: According to Customer specification.
Materials: Stainless steel, Hastelloy, Inconel, other special materials
Connections: According to Customer request

BONETTI Magnetic level gauge Remote Direct Reading SystemMagnetic level gauge MST-X Electronic unit

The Magnetic Level Gauge Type MAG-RDR (Remote Direct Reading) can be installed on any boiler, as a completion of the Glass Level Gauges (which are compulsory) and of the Magnetic Level Gauges.

Two connections on boiler drum are sufficient for installation.

The plant consists of:

  • 1-Connections on boiler drum
  • 2-Condensate container at constant level fitted on top connection, with a vent valve or a plug
  • 3-Downwards pipes
  • 4-Manifold cock for shut-off and reset
  • 5-Mud traps
  • 6-Differential pressure gauge containing a special fluid heavier than water, not water-soluble. One of the two branches of the pressure gauge is fitted with a float containing a magnet moving upwards and downwards depending on water level of drum.
  • 7-Indicating scale for direct level reading outside of differential pressure gauge.

The system can also be extended (See page 14 and following) in details with the installation of:

  • 8-Sensing element positioned externally at float level
  • 9-Signal transmitter current loop type 2 wires, 4÷20 mA (Hart protocol communication available) connecting the sensing element with the control instruments and/or with the indicator/transmitter device MST-X;
  • 10-Indicator/transmitter device MST-X usually installed in the control room equipped with:
    • Output power supply for MST sensing element;
    • Led indicator column (23 red/green bicolour leds);
    • Analogic display indicator with settable configuration (measuring units, zero scale, format, percentage);
    • No. 4 thresholds indicated by leds;
    • Failure signal via yellow blinking led;
    • Output connecting port for PC, industrial PLC for process control and/or data storage;
    • Permanent memory cash for programmable data.
When a magnetic level gauge (12) with another sensing element (13) is fitted on the drum of the same boiler and the signal is transmitted to another transducer (11) to the control room, the comparison between 10 and 11 guarantees the security.

These instruments are patented in Italy as well as in other Countries.

 

Qualification and Standards

  • ISO 9001:2000
  • PED 97/23/EC
  • ATEX 94/9/EC
  • SIL
 

A world leader in Valves

Since 1905 Cesare Bonetti S.p.A. has been manufacturing high performance valves and liquid level indicators, both as standard or as custom designed products to meet the exact requirements of any fluid  pressure and temperature handling application. Thanks to our reputation and experience, our trademarks BONETTI, BONT, CMI and WVE are  recognized worldwide as a guarantee in terms of quality reliability and service to our Customers.